Referring to CB/T3942-2002 flange stainless steel stop valve, suitable for liquefied gas carriers, bulk chemical carriers, and ships' piping systems with nominal pressures not exceeding 6.4 MPa and design temperatures not lower than -165℃. Other ships' piping systems with corrosive media may refer to this valve.
Basic Parameters of the Stop Valve
Type | Nominal Pressure PN MPa |
Operating Temperature, ℃ | Nominal Diameter DN mm | ||||||
≤20 | 100 | 150 | 200 | 250 | 300 | 350 | |||
Maximum Allowable Working Pressure P, MPa | |||||||||
P2 | P10 | P15 | P20 | P25 | P30 | P35 | |||
A, B | 1.0 | 0.95 | 0.86 | 0.81 | 0.76 | 0.71 | 0.66 | 0.36 | 65~150 |
1.6 | 1.52 | 1.31 | 1.29 | 1.21 | 1.13 | 1.06 | 1.01 | 125~150 | |
2.5 | 2.38 | 2.15 | 2.01 | 1.89 | 1.77 | 1.66 | 1.59 | 20~150 | |
4.0 | 3.80 | 3.44 | 3.22 | 3.02 | 2.83 | 2.65 | 2.54 | 65~100 | |
6.4 | 5.69 | 5.26 | 4.96 | 4.68 | 4.41 | 4.16 | 3.92 | 20~15 | |
AS, BS | 0.6 | 0.57 | 0.52 | 0.48 | 0.45 | 0.42 | 0.40 | 0.38 | 15~300 |
1.0 | 0.95 | 0.86 | 0.81 | 0.76 | 0.71 | 0.66 | 0.63 | 200~300 | |
1.6 | 1.52 | 1.31 | 1.29 | 1.21 | 1.13 | 1.06 | 1.01 | 100~300 | |
2.5 | 2.38 | 2.15 | 2.01 | 1.89 | 1.77 | 1.66 | 1.59 | 15~300 | |
4.0 | 3.8 | 3.44 | 3.22 | 3.02 | 2.83 | 2.65 | 2.54 | 65~100 | |
6.4 | 5.69 | 5.26 | 4.96 | 4.68 | 4.41 | 4.16 | 3.92 | 20~50 |
Keyword

Cast steel globe valve
Referring to CB/T3942-2002 flange stainless steel globe valve, suitable for liquefied gas carriers, bulk chemical carriers, and ships' piping systems with nominal pressure not exceeding 6.4MPa and design temperature not lower than -165℃. Globe valves for other ships' piping systems with corrosive media can be used with reference to this standard.
Contact us
Category